Targeted protein panels for focused areas of research
Olink Target 96 measures up to 92 proteins across 88 samples simultaneously, utilizing only 1 µL per sample. The data are reported in relative quantification (NPX), providing valuable insights into protein expression levels. Olink Target 96 includes 15 panels that have been thoughtfully designed to minimize overlap. This means that you have the flexibility to select and combine multiple panels, further expanding your proteome coverage for a more comprehensive analysis.
Olink Target 96 panels
Area of focus | Biomarker panels | Details |
Cardiometabolic | Cardiovascular II | Contains known human cardiovascular and inflammatory markers as well as some exploratory human proteins with great potential as new cardiovascular markers. |
Cardiovascular III | This panel provides a perfect complement to the Olink® Target 96 Cardiovascular II panel, enabling measurement of 184 proteins in 2 dedicated panels. | |
Cardiometabolic | Includes proteins involved in cellular metabolic process, cell adhesion, immune response and complement activation. | |
Immuno-Oncology | Immuno-Oncology | Includes proteins involved in promotion and inhibition of tumor immunity, chemotaxis, vascular & tissue remodeling, apoptosis & cell killing and metabolism & autophagy. |
Immune Response | Includes proteins involved in adaptive immune response, defense response to virus, lymphocyte activation, inflammatory response and cytokine-mediated signaling pathways. | |
Neurology | Neuro Exploratory | A combination of exploratory and established markers with a focus on neurology-related diseases and biological processes, such as axon development, neurogenesis and synapse assembly. The established proteins include Neurofilament light polypeptide (Uniprot no. P07196), which is an important marker for degenerative neurological diseases and traumatic brain injury. |
Neurology | Offers a mix of established markers related to neurobiological processes and neurological diseases, as well as some more exploratory proteins with broader roles in processes such as cellular regulation, immunology, development and metabolism. | |
Oncology | Oncology II | Comprises 92 putative cancer-related human proteins that participate in biological mechanisms that are central to the initiation and progression of cancer. |
Oncology III | This panel provides a perfect complement to the Olink® Target 96 Oncology II panel, enabling measurement of 184 proteins in 2 dedicated panels. | |
Inflammation | Inflammation | The most extensive panel available on the market for proteins associated with inflammatory diseases and related biological processes. |
Biological process | Organ Damage | Includes proteins involved in response to stress, regulation of cell proliferation, cell cycle, and cell death/apoptosis. |
Development | Includes proteins involved in cell migration & motility, extracellular matrix organization and neurogenesis. | |
Metabolism | Includes proteins involved in cellular metabolic processes, cell surface receptor signaling pathways, regulation of phosphorylation and cell adhesion. | |
Cell Regulation | Includes proteins involved in cell communication, apoptotic process, cell cycle and cell differentiation. | |
Mouse Exploratory | Includes proteins involved in cellular regulation, development, signal transduction and stress responses. |
Inflammatory assay for cytokine studies and inflammation-related diseases
Olink Target 48 Cytokine conveniently analyzes 45 human proteins associated with inflammation, allowing you to gain valuable insights into the complex mechanisms involved in cytokine signaling and inflammatory responses. The proteins are measured simultaneously across 40 samples, utilizing only 1 µL per sample. The results obtained through this ready-to-use panel are reported in absolute quantification (pg/mL), providing you with precise measurements of protein levels.
Olink Target 48 Mouse Cytokine enables measurement of 43 proteins associated with inflammation, immune response and immuno-oncology for a comprehensive view of the murine immune system. The proteins are measured simultaneously across 40 samples, utilizing only 1 µL per sample. The results obtained through this ready-to-use panel are reported in absolute quantification (pg/mL), providing you with precise measurements of protein levels. The minimal sample volume is a breakthrough in disease modelling, allowing repeated biomarker analysis from the same mouse in longitudinal studies.
Mix-&-match assay for tailored, flexible results
Olink Flex gives you the freedom to customize and create a made-to-order assay capable of measuring up to 21 human proteins concurrently across 40 samples. Protein targets can be selected and combined from a library of approximately 200 inflammation-related human proteins with an impressive 99% combinability. Moreover, only 1 µL per sample is required per Olink Flex panel, with results reported in both absolute quantification (pg/mL) and relative quantification (NPX).