Cookie Settings

We use cookies to optimize our website. These include cookies that are necessary for the operation of the site, as well as those that are only used for anonymous statistic. You can decide for yourself which categories you want to allow. Further information can be found in our data privacy protection .

Essential

These cookies are necessary to run the core functionalities of this website and cannot be disabled.

Name Webedition CMS
Purpose This cookie is required by the CMS (Content Management System) Webedition for the system to function correctly. Typically, this cookie is deleted when the browser is closed.
Name econda
Purpose Session cookie emos_jcsid for the web analysis software econda. This runs in the “anonymized measurement” mode. There is no personal reference. As soon as the user leaves the site, tracking is ended and all data in the browser are automatically deleted.
Statistics

These cookies help us understand how visitors interact with our website by collecting and analyzing information anonymously. Depending on the tool, one or more cookies are set by the provider.

Name econda
Purpose Statistics
External media

Content from external media platforms is blocked by default. If cookies from external media are accepted, access to this content no longer requires manual consent.

Name YouTube
Purpose Show YouTube content
Name Twitter
Purpose activate Twitter Feeds
X-Ray Imaging and Computed Tomography

Abdomen Phantom

Stefan Schaller

The aim of this phantom is to study the properties of cone-beam image reconstruction algorithms based on simulations. A typical diagnostic problem in the abdominal region is the detection of liver lesions. Demands on high contrast resolution are moderate, but artifacts occasionally bury anatomical low-contrast structures.

Phantom Description

Our phantom consists of a main body, modeled by an elliptical cylinder 40cm wide and 24cm thick. An ellipsoid of dimensions 14cm x 16cm x 20cm models the liver. We have put low-contrast lesions into the liver. The contrast is 10 HU. The lesions are represented by spheres with diameters 2mm, 3mm, 4mm, 5mm, 6mm, 8mm, 10mm and 12mm respectively. Lesions are placed both in the plane at z=0 and in the plane at z=3cm. There are 5 vertebrae at z=-10cm, -5cm, 0cm, 5cm and 10cm. Particular problems arise at long straight contrast edges, such as liquid/air surfaces. To be able to study that particular problem, we have put into the phantom a hollow object, which is partly filled by a liquid. Another major cause of artifacts in spiral CT scanning are high contrast structures tilted with respect to the axis of rotation. Our phantom therefore contains two ribs on the left and right, tilted by 60 degrees with respect to the longitudinal axis. The phantom also contains high contrast insets that allow us to verify that a desired high contrast resolution has been achieved. Resolutions are 10 lp/cm and 12 lp/cm both in azimuthal and radial direction respectively. (Note: The vertebrae are defined in a separate include file.)

Files

•    Phantom Definition
•    Zip File
•    Syntax Explanation